Login for Dealers

MP-2

Advantages:

  • a wide range of measurement functions and measured quantities;
  • indicator of decimal digit 3 3/4;
  • measuring of root mean square values True-RSM
  • impact-resistant body.

Range Overview

Technical characteristics

The choice of the measuring range manual
The maximum value of the display 1999
Direct voltage:
limits of measurement 200 mV, 2, 20, 200, 1000 V
error 1,0 %
max.  resolution 0,1 mV
input impedance 10 MOhm
Alternating voltage:
limits of measurement 2, 20, 200, 750 V
error 1,5 %
max.  resolution 1 mV
полоса частот  50 to 500 Hz
input impedance 10 MOhm / 50 pF
Direct  current:
limits of measurement 200 µА, 2, 20, 200 mA, 10 А
error 1,2 %
max.  resolution 0,1 µА
Alternating current:
limits of measurement 200 µА, 2, 20, 200 мА, 10 А
error 1,5 %
max.  resolution 0,1 µА
frequency band 50 to 500 Hz
Resistance:
limits of measurement 200 Ohm, 2, 20, 200 kOhm, 2, 20 MOhm
error 1,0 %
max.  resolution 0,1 Ohm
Frequency:
measurement range from 2 Hz to 1 MHz
error 0,5 %
Capacity:
measurement range 4 nF - 40 µF
error 0,8 %
Temperature:
measurement range from -20 to  +1000 °С
error 2 %
Other features:
The gain of transistor h21 yes
The regime continuity yes
Offset correction mode no
Data Hold yes
Diode test yes
Battery Low yes
Display Illumination yes
Auto shut-off no
Input protection yes
Power supply 6F22 alkaline (КРОНА)
Operating conditions (+ 5 ... + 40) °С, rel.  humidity up to 80%
Dimensions 147 Х 75 Х 40 mm
Weight without battery 0,35 kg